SPIRO, Spiro, project for student, student projects
A RESEARCH & DEVELOPMENT ORGANIZATION

For Project Enquiry +91 9962 067 067

Slideshow Image 1
Post Your concept Get Project
Guidance
It is purposely dedicated for innovative students. Here we encourage students who have new concepts and projects in various domains.

For Project Title


Project Zone > Electrical > Power Electronics

Social share: Facebook SPIRO Google Plus

A quasi-unipolar SPWM full-bridge transformer less pv grid-connected inverter with constant common-mode voltage

Category : Power Electronics


Sub Category : DC TO AC CONVERTERS (INVERTERS)


Project Code : ITPW19


Project Abstract

The unipolar sinusoidal pulse width modulation (SPWM) full-bridge transformer less photovoltaic inverter with ac Bypass brings low conduction loss and low leakage current. In order to better eliminate the leakage current induced by the common mode voltage, the clamping technology can be adopted to hold the common-mode voltage on a constant value in the freewheeling period. A full-bridge inverter topology with constant common-mode voltage (FB-CCV) has been derived and proposed in this paper, two unidirectional freewheeling branches are added into the ac side of the FB-CCV, and the split structure of the proposed freewheeling branches does not lead itself to the reverse-recovery issues for the freewheeling power switches and as such super junction mosfets can be utilized without any efficiency penalty. The passive clamping branches consist of a capacitor divider and two Diodes, is added into the dc side of the FB-CCV, therefore, the Weakness of active damping branch has been overcome, and the Better clamping performance has been achieved in the freewheeling Period. In the dead time between the main switches and the Freewheeling switches, the ant parallel diodes of diagonal main Switches of the FB-CCV form the freewheeling path to clamp the Common-mode voltage at a constant value, and a quasi-unipolar SPWM strategy is presented. The operation principle, differential mode, And common-mode characteristics of the FB-CCV, Heric, H6, and HB-ZVR topologies are analyzed and compared in detail. Finally, the viability of the FB-CCV is verified by a universal Prototype inverter rated at 5 kw.

EXISTING SYSTEM

 

PROPOSED SYSTEM

                                   

This project focuses on improving the leakage current suppressionperformance of the Heric topology.

 

the quasi SPWM differential-mode voltage is a combination of unipolar and bipolar SPWM, and is more close to the unipolar SPWM.

 

It performs only one operation highest hard-switching conversion efficiency

 

Two operation modes in the freewheeling period: the dead-time freewheeling mode and zero-vector freewheeling mode.

 

It is not suitable for lower switching frequency.

 

Two operation modes in the freewheeling period: the dead-time freewheeling mode and zero-vector freewheeling mode.

 

less efficiency

 

high efficiency

 

 

 
 
MILE STONES
GUARANTEES
CONTACT US
 
Training and Developemet, Engg Projects
So far we have provided R&D training for more than 1,00,000 engineering Students.
Latest Projects 2012, Latest Technologiy Project
Had conducted seminars in the recent trends of technology at various colleges.
Our research projects had been presented in various National & International Conferences.
Most of our projects were identified by the industries as suitable for their needs.
Our n-number of students got research scholarship to extend our assisted projects for further development.
   
   
Training and Developemt, Project Development in Chennai
SPIRO guarantees small class sizes.
Final Year Projects
SPIRO guarantees quality instructors.
Student Projects, Stupros
SPIRO guarantees competence.
Projects, student projects
SPIRO guarantees that training from SPIRO will be more cost-effective than training from any other source.
Final Year Projects, Projects, student projects
SPIRO guarantees that students in open-enrollment classes are protected against cancellations and will be able to receive desired training at the cost they expect and in the time frame they have planned.
Projects for student
SPIRO guarantees overall quality with a 100% money-back guarantee. If you're not totally satisfied for any reason, simply withdraw before the second day of any class. Notify the instructor and return all course materials and you will receive a 100% refund.
SPIRO SOLUTIONS PRIVATE LIMITED
For ECE,EEE,E&I, E&C & Mechanical,Civil, Bio-Medical
#1, C.V.R Complex, Singaravelu St, T.Nagar, Chennai - 17,
(Behind BIG BAZAAR)Tamilnadu,India
Mobile : +91-9962 067 067, +91-9176 499 499
Landline : 044-4264 1213
Email: info@spiroprojects.com

For IT, CSE, MSC, MCA, BSC(CS)B.COM(cs)
#78, 3rd Floor, Usman Road, T.Nagar, Chennai-17.
(Upstair Hotel Saravana Bhavan) Tamilnadu,India
Mobile: +91-9791 044 044, +91-9176 644 044
E-Mail: info1@spiroprojects.com
About Us | Project Training | Privacy policy | Disclaimer | Contact Us

Copyright © 2015-2016 Stupros All rights reserved.